  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7. 8.Revisions proposed to Recommendation 0.162
  8.  
  9.        Change the existing title to:
  10.  
  11.        "EQUIPMENT TO PERFORM IN SERVICE MONITORING ON 2048 KBIT/S SIGNALS"
  12.  
  13.        Change  1.1 to read:
  14.  
  15. "1.1   This specification describes an instrument for performing in-service 
  16. error tests on 2  Mbit/s  signals  having  frame  structures  that  are  in
  17. accordance with Recommendation G.704 [1]."
  18.  
  19.        Introduce new  1.4 and 1.5 as follows:
  20.  
  21. "1.4   The instrument is required to monitor any Cyclic  Redundancy  Check  (CRC)
  22. Procedure signals, in accordance with Recommendation G.704 [1],  conveyed  within
  23. the frame alignment signal, and time slot 0 (TSO) of frames  not  containing  the
  24. frame alignment signal.
  25.  
  26. 1.5    As an option the instrument may provide access  to  the  information  bits
  27. conveyed in any selected time slot."
  28.  
  29.        Renumber existing  1.4 to "1.6 HDB3 Decoding Strategy".
  30.  
  31.        Change the references to Recommendation G.732 in  3.3.3.1 and 3.3.3.2 to 
  32. Recommendation G.706".
  33.  
  34.        Add the following note after  3.3.3.2:
  35.  
  36. "Note - The instrument shall be able to synchronize to frames with or without CRC 
  37. bits."
  38.  
  39.        Change the term "error rate" to: "binary error rates" in  3.3.4.1  (three
  40. times) and in Table 1/0.62 (two times).
  41.        Introduce the following new section 3.4 in the Recommendation:
  42.  
  43. "3.4   Cyclic redundancy check procedure
  44.  
  45. 3.4.1  Where a  Cyclic  Redundancy  Check  (CRC)  procedure  in  accordance  with
  46. Recommendation G.704 [1] is implemented within the 2 Mbit/s signal the instrument shall 
  47. provide the features detailed in  3.4.2, 3.4.3 and 3.4.4.
  48.  
  49. 3.4.2  The instrument shall indicate the presence of CRC framing bits.
  50.  
  51. 3.4.3  The instrument shall have a means of indicating binary error ratios of 1 x 
  52. 10-5, 1 x 10-6 and 1 x 10-7 and shall  cause  the  appropriate  indicator  to  be
  53. illuminated under the conditions defined.
  54.  
  55.        The indication of binary error ratios occurring in  the  received  decoded
  56. signal and detected by means of the CRC procedure information shall comply with the 
  57. limits given in Table 2/0.162.
  58.  
  59.                                  TABLE 2/0.162
  60.  
  61. ┬───────────┬───────────────┬───────────────────────────────────────────────┐ 
  62.  │Binary     │ Average       │ Probability of indication illuminating or     │ 
  63.  │error ratio│ binary error  │ extinguishing within the periods stated below │ 
  64.  │indication │ ratio in      ├─────────────────────────┬─────────────────────┤
  65.  │           │ decoded signal│         Illuminate      │   Extinguish        │ 
  66.  
  67.  
  68.  
  69.  
  70.  
  71.  
  72.  
  73.  
  74.  
  75.  
  76.  
  77.  ├───────────┼───────────────┼─────────────────────────┼─────────────────────┤
  78.  │           │   1 x 10-5    │       50% within 1s     │    5% within 1s     │   │ 
  79.  1 x 10-5 │   5 x 10-6    │        5% within 1s     │         -            │    │
  80.        │   1  x  10-6     │                -          │    95%  within  1s      │
  81. ├───────────┼───────────────┼─────────────────────────┼─────────────────────┤
  82.  │           │   1 x 10-6    │       50% within 10s    │    5% within 10s    │ 
  83.  │  1 x 10-6 │   5 x 10-7    │        5% within 10s    │         -           │
  84.  │           │   1 x 10-7    │               -         │   95% within 10s    │
  85.  ├───────────┼───────────────┼─────────────────────────┼─────────────────────┤ 
  86.  │           │   1 x 10-7    │       50% within 100s   │    5% within 100s   │   │ 
  87.  1 x 10-7 │   5 x 10-8    │        5% within 100s   │         -           │
  88.  │           │   1 x 10-8    │               -         │   95% within 100s   │ 
  89.  └───────────┴───────────────┴─────────────────────────┴─────────────────────┘ 
  90.  
  91.  
  92. 3.4.4  It shall also be possible to count the sum of the  errors  indicated.  The
  93. count capacity shall be 99 999. A separate indication shall be given if the count 
  94. exceeds this figure."
  95.  
  96.        Renumber the existing  3.4 to "3.5 Code violation detection"
  97.  
  98.        Introduce a new  3.6 as follows:
  99.  
  100. "3.6   Performance indications
  101.  
  102.        As an option the instrument shall  be  capable  of  providing  performance
  103. information in accordance with G.821 - Under Study".
  104.  
  105.        Renumber the existing  3.5 to "3.7 Lamp look - Lamp auto reset".
  106.        Introduce a new  3.8 as follows:
  107.  
  108. "3.8   Time slot access
  109.  
  110.        As an option it shall be possible to access, at an external interface, the 
  111. contents of any selected time slot, including TS16. An external interface meeting 
  112. the requirements of a co-directional interface, as defined in Recommendation G.703 
  113. [2], is preferred."
  114.  
  115.        Introduce a new  4.2 as follows and renumber the existing  4.2 to     "
  116. 4.3":
  117.  
  118. "4.2   References to counters and displays  being  illuminated  and  extinguished
  119. does not imply that "light emitting" displays are essential".
  120.  
  121.        Replace the existing sections 6 and 7 by the following ones:
  122.  
  123. "6.    Alarm output signal
  124.  
  125.        As an option, an interface shall be provided to enable an external device, 
  126. e.g. printer, to be connected to the instrument to allow recording of the  status
  127. of the digital signal input to the instrument.
  128.  
  129.        An  interface  in  accordance  with  Recommendation  V.24/V.28,   carrying
  130. suitably abbreviated, plain text messages in ASCII/T.50 coded format according to the 
  131. requirements of Recommendation V.4 is preferred.
  132.  
  133. 7.     Operating environment
  134.  
  135.        The electrical performance requirements shall be met when operating within 
  136.  
  137.  
  138.  
  139.  
  140.  
  141.  
  142. the climatic conditions specified in Recommendation 0.3."
  143.  
  144.        Delete the existing Tables 2/0.162 and 3/0.162 from the Recommendation.  
  145.  
  146.  
  147.  
  148.                                  ─────────────── 
  149.  
  150.  
  151.  